Back to Operable Walls

Kwik-Wall 3000 Series Operable Wall

A nominal 4-inch operable wall family for demanding room layouts and acoustic requirements. Choose individual panels, hinged pairs or continuously hinged electric operation, with construction-specific STC options up to 56.

Kwik-Wall 3000 Series operable wall with glazed inserts

Details that make the difference.

Applications

Divide large conference rooms, hotel meeting and banquet spaces, convention facilities and multi-purpose rooms. Individual panels support complex layouts and remote storage; paired and electric systems suit straight-run division. Coordinate clear openings, egress, stacking and overhead support early in design.

Configurations

3010 — Manual individual panels, pre-programmed carriers on radius curve-and-diverter track; offset or remote storage. 3020 — Manual individual multi-directional panels negotiating 90-degree X, L and T intersections; offset or remote storage. 3030 — Manual hinged pairs for straight-run layouts with centerline or bi-parting stacking. 3050 — Continuously hinged electric panel train for straight-run division, with centerline or bi-parting arrangements. Coordinate power, controls and opening limits with the selected construction.

Technical specifications

PANEL CONSTRUCTION Nominal 4 in. (101.6 mm) panels with roll-formed steel frames. Steel skins are standard; acoustic-substrate constructions support compatible finishes and have their own tested ratings. FINISHES & OPTIONS Current model sheets list vinyl, fabric, carpet, high-pressure laminate, wood veneer, digitally printed steel and manufacturer-approved customer-supplied materials. HPL and veneer require acoustic-substrate selection. Pass doors, pocket doors, marker/tack surfaces, invisible hinges and insulated-glass inserts depend on model and configuration. TRACK & PROJECT COORDINATION Select track and carriers for panel construction, height, loads and storage layout. Coordinate structural support, floor levels, plenum barriers, electrical controls for Model 3050, closure panels and adjoining construction through manufacturer shop drawings. Opening limits vary by model and substrate; verify the selected configuration rather than applying a family maximum.

Performance ratings

JUNE 2026 SOLID-PANEL OPTIONS Steel skin: 46S, 50S, 52S and 56S. Acoustic substrate: 43A, 46A, 48A and 50A. A denotes acoustic substrate; S denotes steel skin. These are discrete tested constructions, not every rating between 43 and 56. The current 3010, 3020, 3030 and 3050 technical sheets list these selections. Finish, seals and accessories must match the tested assembly. Insulated-glass insert panels require separate acoustic data; solid-panel ratings must not be applied to glazing. STC tests use ASTM E90 and ASTM E413.

Technical documents

Visit Technical Resources